Specifications Units SS250PLC SS500PLC SS1000PLC SM1500PLC
Ozone Production (oxygen feed) lb/day N/A 5.0 10.0 15.0
Ozone Production (oxygen feed) g/hr N/A 95 189 284
Ozone Production (air feed) lb/day 2.5 2.5 5.0 7.5
Ozone Production (air feed) g/hr 47 47 95 142
Feed Gas Flow (range) scfh 10-50 10-50 20-100 30-150
Feed Gas Flow (optimal) scfh 50 50 100 150
Ozone Concentration (oxygen feed) %/wt N/A 3-8% 3-8% 3-8%
Ozone Concentration (air feed) %/wt 1-2% 1-2% 1-2% 1-2%
Feed Gas Pressure psi 15 15 15 15
Ozone Production Control Range % 0-100 0-100 0-100 0-100
Cooling Water Required gpm 0.5-0.75 0.5-0.75 1.0-1.5 1.5-2.0
Gas/Water Fittings inch 3/8" 3/8" 3/8" 3/8"
Power Requirement volt, Hz 240 VAC, 50/60 Hz, 1 phase
Power Consumption watt 2.1 kWh 3.0 kWh
Main Power Breaker Requirement amp 12 15 20 20
PLC Control yes yes yes yes
Remote Signal mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA
Dimensions (L x W x H) inch 48" x 30" x 10" 48" x 30" x 10" 48" x 30" x 10" 48" x 36" x 16"

Specifications Units SM2000PLC
Ozone Production (oxygen feed) lb/day 20
Ozone Production (oxygen feed) g/hr 378
Ozone Production (air feed) lb/day 10
Ozone Production (air feed) g/hr 189
Feed Gas Flow (range) scfh 40-200
Feed Gas Flow (optimal) scfh 200
Ozone Concentration (oxygen feed) %/wt 3-8%
Ozone Concentration (air feed) %/wt 1-2%
Feed Gas Pressure psi 15
Ozone Production Control Range % 0-100
Cooling Water Required gpm 2-3
Gas/Water Fittings inch 3/8"-1/2"
Power Requirement volt, Hz 240 VAC, 50/
Power Consumption watt 3.0 kWh
Main Power Breaker Requirement amp 30
PLC Control yes
Remote Signal mA 4-20 mA
Dimensions (L x W x H) inch 26" x 26" x 78"

Specifications Units SL30PLC SL60PLC SL120PLC
Ozone Production (oxygen feed) lb/day 30 60 120
Ozone Production (oxygen feed) g/hr 567 1134 2268
Ozone Production (air feed) lb/day 15 30 60
Ozone Production (air feed) g/hr 284 567 1134
Feed Gas Flow (range) scfh 185-375 370-745 745-1490
Feed Gas Flow (optimal) scfh 375 745 1490
Ozone Concentration (oxygen feed) %/wt 3-8% 3-8% 3-8%
Ozone Concentration (air feed) %/wt 1-2% 1-2% 1-2%
Feed Gas Pressure psi 15 15 15
Ozone Production Control Range % 0-100 0-100 0-100
Cooling Water Required gpm 3.0-3.5 6.0-6.5 12.-12.5
Gas/Water Fittings inch 1" 1" 1"
Power Requirement volt, Hz 240 VAC, 50/60 Hz, 3 phase
Power Consumption watt 3.6 kWh 7.2 kWh 15.36 kWh
Main Power Breaker Requirement amp 30 40 80
PLC Control yes yes yes
Remote Signal mA 4-20 mA 4-20 mA 4-20 mA
Dimensions (L x W x H) inch 72" x 48" x 54" 72" x 48" x 54" 72" x 48" x 72"