Specifications Units SL60PLC
Ozone Production (oxygen feed) lb/day 60
Ozone Production (oxygen feed) g/hr 1134
Ozone Production (air feed) lb/day 30
Ozone Production (air feed) g/hr 567
Feed Gas Flow (range) scfh 370-745
Feed Gas Flow (optimal) scfh 745
Ozone Concentration (oxygen feed) %/wt 3-6%
Ozone Concentration (air feed) %/wt 1-2%
Feed Gas Pressure psi 15
Ozone Production Control Range % 0-100
Cooling Water Required gpm 6.0-6.5
Gas/Water Fittings inch 1"
Power Requirement 240 VAC, 60 Hz, 3 phase
Power Consumption watt 7.2 kWh
Main Power Breaker Requirement amp 40
PLC Control yes
Remote Signal mA 4-20 mA
Height inch 54"
Width inch 48"
Depth inch 72"
Weight lb.
sl60plc
 

Safety and Design Features


Soft start: All generators are equipped with a soft start function which prevents the power from coming up too quickly. This function extends the life of the dielectrics.

Heat sensors: A thermistor circuit in the generator senses the temperature of the cells on the output side of the system. If cell exceeds temperature, the generator will automatically shut down and provide a visual indication that the cell has overheated.

Water sensor: Checks for moisture in the ozone line and ozone cell. If water is detected, system shuts down immediately to protect cell(s). Fault message will appear on LCD display indicating the presence of moisture.

Feed gas pressure sensor: Monitors pressure of feed gas (oxygen or dry air) to insure that an adequate pressure is being maintained. Should pressure fall below operating parameters, system will shut down and fault message will appear on LCD display indicating low feed gas pressure.

Water pressure sensor: Monitors pressure of cooling water to insure that an adequate supply of cooling water is maintained. Should pressure fall below operating parameters, system will shut down and fault message will appear on LCD display indicating low water pressure.

High/low current sensor: Monitors cell current to ensure that a consistent level of ozone production is maintained. Should current fall below or exceed normal operating parameters, system will shut down and fault message will appear on LCD display indicating a current fault.